Category Archives: Uncategorized

Square D Homeline Circuit Breakers: Cost and Availability King

SELF TAUGHT ?

Learning without safety with knowledge, not sound,

learning by trial, by others not taught,

often had brought a disturbing shock.

If the body had firm path, from heart to ground,

surprise of shock would be more than a squawk.

(c) 3-02-2022 – Roger W Hancock

THE GREAT SEATTLE BANANA SHORTAGE – EVERY CRISIS, ANY YEAR

Times are hard.  Material availability difficulties have been the hallmark driving delays within the construction industry.  Thats why Safe and Sound Electric can help consumers make informed decisions on the products they patronize in their home.

I’ve been given so many reasons for material shortages delays; the Evergiven being stuck, hurricanes in the Dominican Republic, the Texas storm, COVID-19, and countless others.  Bottom line is there are breakers that are required to be installed by code and they cannot be purchased from every manufacturer.  The shortage could be likened to having to go to Safeway for eggs, but they are out of milk so you must go to Costco for the milk.  A dedicated electrician knows how to find solutions, commonly same day to solve material shortage woes.

As an informed consumer ourselves, we would like to know which store has a banana for sale and is fair value.  I don’t want you to be stuck searching craigslist for breakers or trying to buy them from amazon retailers for inflated prices.

So here are our Availability and Cost picks for 2022:

Square D Homeline

No surprise here Homeline is the most available and most competed for breaker product you can buy.  If you want to be sure your project is done on time with minimal surprises go Homeline.

GE

ABB must be doing something different than Cooper.  We’ve had good experience procuring GE brand breakers and a number of retailers and wholesalers.

Leviton

This is a surprise.  While not available everywhere, Leviton breaker products are very widely available after they changed from a hydraulic magnetic to a thermal magnetic trip unit.

Siemens

We would put GE, Leviton, and Siemens in the same tier for cost and availability.

5 Products Safe and Sound Electric can install in your home that save money

Does an Energy Monitor Save You Money?

A monitor alone won’t save you money but changing your habits will. All that an energy monitor does is provide accurate electricity usage data to help you identify energy inefficiency, make informed decisions, and track your progress toward energy reduction goals.

An energy monitor is a wonderful way to discover power-hungry appliances that may be perniciously stealing energy. This may be a device that you forgot to turn off, an always-on appliance that consumes more electricity than you’d expect or something that isn’t operating properly. Such energy hogs can easily go unnoticed but will show up loud and clear with a monitor like Sense.

Sense reports its average user saves 9% on electric bills. Given the average monthly electric bill is $117, or $1,400 per year, an energy monitor saves the average homeowner $126 annually and will pay for itself in about two and a half years.

Sense Energy Monitor

The Sense Energy Monitor with Solar’s dashboard has built-in cost calculations to compare the energy produced and energy consumed in a side-by-side view, information that can minimize the amount of power to purchase. The longer it’s plugged in, the more this monitor learns, which helps the monitor determine patterns in energy use and find ways to improve.

The Sense monitor identifies individual appliances and offers information about specific devices: when they’re on, their efficiency, vampire tendencies, and more. The energy monitor sends notifications about potential issues, including solar system alerts. Sense fits right into the electrical panel and is best installed by a certified electrician. It then connects the home to a smartphone via the power of Wi-Fi.

Pros

  • Whole-house energy monitoring system
  • Tracks solar generation and output
  • Customizable notifications

Cons

  • No ethernet port option
  • Slow to identify devices

Emporia Energy Gen 2 Vue Smart Home Energy Monitor

Receive up-to-the-moment data about energy cost and usage anytime and anywhere with EMPORIA ENERGY’s Gen 2 monitor. The monitor comes with 16 sensors that clamp onto the main and individual circuits in the breaker box, which are best attached by a professional, though they come with DIY instructions.

The device monitors larger appliances attached to the individual circuits, but it integrates with smart plugs (not included) to monitor smaller appliances, set timers and schedules, and increase control through the EMPORIA ENERGY app. Solar homes can use this monitor to see how much excess energy goes back to the grid versus how much energy the home consumes. The app sends notifications based on the data it gathers, so users know which steps to take to conserve energy and control costs.

Pros

  • Eight sensors included, but eight more can be purchased
  • Solar generation net metering capabilities
  • Customizable push notifications

Cons

  • Data collected and stored on cloud, not your own device
  • Difficult to retrieve extra data if desired

Eyedro Home Energy Monitor

See the real-time costs of energy use with this easy-to-use home energy monitor from Eyedro. Its sensors clip into an electrical panel to feed information to an online dashboard using the provided Ethernet cable, but it also has a Wi-Fi option. Log in to the Eyedro website to see energy usage any time, even when away from the house.

As appliances turn on and off, the change to energy consumption displays as an update on a phone or computer screen. Through the dashboard, access monitoring reports and bill estimates and receive alerts if the power goes out at home and the system loses communication. Install this energy monitoring system into an electrical panel in as little as 15 minutes with the included instructions.

Pros

  • Ethernet connection option for reliable internet
  • Plenty of data options to review
  • No subscription fees

Cons

  • Only two monitoring clips
  • Poor installation can cause inaccurate readings

Nest Thermostat

Safe and Sound Electric can also help with that c wire issue you may be having.

The need to save money on heating and cooling cannot be overemphasized. There are diverse ways you can achieve this, and the Nest (the first smart thermostat to hit the market) can be immensely helpful. Also regarded as the “learning” thermostat, the Google Nest has many benefits and a few advantages. We will highlight the most important ones below:

Pros

  • It will save energy and money – Energy-efficiency is one of the biggest benefits smart thermostats like Nest offers. The Google Nest can significantly lower your energy consumption, and this means it can save you lots of money overall. It will also cut carbon emissions.
  • It makes controlling your AC easier – Google Nest makes controlling your AC a lot easier. It allows you to use your smartphone to control your home temperature, even when you are far from home.
  • It allows for multiple settings – Google Nest gives you more control over your AC setting because it is programmed with multiple settings. You can even control the temperature in individual rooms.
  • You can set it and forget it – As a “learning” thermostat, the Google Nest will make you become energy-conscious with minimal effort. When properly programmed, you can leave it to do all the job of temperature control.
  • It can be fun for techies – Smart thermostats are fun to use, and Google Nest is a lot of fun for techies. It will help you monitor and control your home temperature in a fun manner.

Cons

  • Compatibility issues – Google Nest may not be compatible with your existing AC unit, meaning you will need to invest in a new system. You may also need a C-wire installation to make it compatible.
  • The price tag – Google Nest is expensive. It is even much more expensive than other smart thermostats.

Leviton Main Panel

If you are considering a panel replacement job for your home, consider a Leviton main panel.  These panels feature breakers that not only monitor your energy consumption but also can be turned off from your smart phone (yes, we can also install the plexiglass see-through cover also)

Pros

  • Smart breakers are controllable remotely – Shut off a problem before it does damage, or on high energy use
  • Wonderful addition to a Leviton Main Panel – You don’t need to buy the Smart breakers at initial installation, you can purchase them later for a spiffy upgrade

Cons

  • The AFCI functionality to our knowledge is of the Current Transformer (CT) variety therefore on an older house with potential circuit collisions or multi-wire branch circuits a Leviton may not be the best choice.
  • Oil filled breaker debacle – The Leviton breakers were originally oil filled and made in Mexico.  They later switched to vacuum sealed thermo-magnetic trip breakers from China.  The Oil filled breakers truly made the technology of this panel ahead of the curve.  They are no longer available.
  • Price – The panel, and its breakers are more expensive than alternatives
  • Availability – Leviton as a brand is not carried at Lowes

Do you need an “Electrician near me“?

Don’t hesitate to callemail, or fill the form here  an “Electrician near me” (Safe and Sound Electric) will be in contact shortly.

Portions of this article have been taken from bob vila Tried, True, Trustworthy Home AdviceEcoWatchWaychoff’s Air Conditioning Clean. Smart. Professional.

Lutron Rotary Dimmer Sports Redesign

From Lutron’s Website:

The original solid-state dimmer, introduced in 1961, sets lights for the perfect mood or ambiance. Rotate to select light level, and either rotate or push to on/off.

  • Features & Specifications
  • Large, easy-to-use knob
  • Available in white or ivory
  • Models available with locator light
  • Matching fan-speed controls available
  • Matching Fassada gloss wallplates available for 1-gang up to 3-gang sizes
  • Electrostatic discharge tested
  • Mechanical air-gap switch to disconnect load power
  • RFI suppression
  • Underwriters Laboratories and Canadian Standards Association listed
  • Lutron controls are rated at 120 VAC, 60 Hz unless otherwise noted

Upon further review the dimmer only does incandescent and halogen loads.  What would it take to have a knob controlled triac dimmer with digital fade that catches up to your analogous turning motions?  I guess we won’t know for now.  These rotary dimmers are just like your step-mother: the new design may seem appealing but underneath its still the same tired 1960’s resistor dimmer that everyone’s had a turn on.  This coupled with the fact it will only take incandescent and halogen loads are the reasons Safe and Sound Electric cannot recommend these.

If you’d like to install a dimmer, contact Safe and Sound Electric. Safe and sound electric is a premier installer of dimming products for lighting equipment but check out all of our other services also!

Siemens Breakers are O.K. Too

In Out article titled “Why GE AFCI Breakers are Ahead of the Curve” We explored the reasons why GE THQL Arc Faults were superior to all other manufacturers’ offerings. 

Today we recognize Siemen’s unique offerings which put them ahead of the curve.

The first feature that Siemens’ new breakers offer is the same advantage GE

SLASH RATED 120V/240V BREAKER

has with its electronic trip unit.  You no longer need to land the neutral on the breaker.  This is all fine and good, there is one major caveat to these breakers which set them behind the GE Arc faults in terms of compatibility: The tandem and single pole Siemens are not “Slash Rated” (read on label as 120/240v)

So you cannot use handle ties.  This gives GE one significant advantage over the Siemens.

There are 2 features that Siemens offer however which make them superior for remodel homes with Siemens or Murray (Yes Siemens breakers are rated for Murray Panels) Main Circuit Breaker Panels, and new construction.

Wire insertion tab indicator

The yellow tabs push in to the case of the breaker as wire is inserted giving

WIRE INSERTION INDICATOR FLAG

the installer feedback of how deep the conductor should be allowing for and even deeper chin of the molded case to tunnel through before you are in the lug.

We see this feature as muted as the design of the breaker has changed to have a deeper chin, perhaps you will actually need this feedback since it will be more difficult to maneuver the conductor in to place through the expanded case and onto the lug.

Tandem (Peanut) Breakers

Technically peanut breakers are 1/2 size individual breakers, specifically

TANDEM (PEANUT) BREAKERS

made by GE.  Tandem breakers are Peanut’s younger half sibling; they wish they were the original Peanut but are hindered by their inflexibility.

It is nice that Siemens offers essentially 1/2 sized breakers for say that old 20/40 space Murray you may find on occasion and need to sneak a new circuit in.  On New Construction this will also be a  boon as the price point of these considering they are 2 breakers in 1 spot essentially cut costs back to wholesale value in a retail package.

For the Safety Minded Customer

Both GE and Siemens are ahead of the curve in our opinion.  There are situations where Siemens would be more ideal than GE and vice versa.  If you’d like help in your next electrical project don’t hesitate to Countact Safe and Sound Electric, your Kitsap Electrician Call us: 360-633-5413 Text us: 360-633-5413 or email us: info@safesoundelectric.com

Why GE AFCI Breakers are Ahead of the Curve

At Safe and Sound Electric we do a lot of remodels.  There are a few conditions in older homes that cause AFCI or arc fault breakers to trip.  One of the most common causer of this is circuit collisions not on the phase but on the neutral.  We see countless number of homes that would be otherwise incompatible with AFCI or arc fault technology because the previous electrician did not segregate neutrals from different circuits.

This is no longer a problem using GE AFCI or arc fault circuit breakers.  The nomenclature THQL120AF2 denotes the generational difference of circuit breakers with this technology.  If the circuit breaker ends in “AF2” it does not matter if the downstream neutral is shared; in fact the downstream neutral doesn’t even need to be landed on the breaker itself, contrary to all breakers made by any competitor.  “AF1” and GE’s competitor’s current breakers used a similar same electronic tripping mechanism as a GFCI or ground fault but instead of tripping at 5mA they trip at 30mA.

For this reason Safe and Sound Electric recommends GE panels.

  1. What is AFCI Protection? AFCI protection guards against damage or fires that can result from arcing and sparking circuits. Arc faults can occur from conditions that include deteriorated wires, poor connections and breaches in wire insulation. With more than 47,000 home fires claiming more than 455 lives and injuring 1,500 victims and $1.5 billion in property damage from 2007 – 2011* annually, the added safety provided by AFCI protection is an important step forward in reducing this risk. * Reference sourced from NFPA.org
  2. What is an AFCI with shared neutral? An AFCI with shared neutral consists of two one-pole GE circuit breakers that are tied together with a handle tie, forming a simple, two-pole shared neutral solution.
  3. What makes the neutral “shared”? In a typical application, a single #14/3 or #12/3 wire is run to a location that is close to the utilization area. The neutral wire is then split, one goes with the red wire and one goes with the black wire. Ordinarily you would not be able to have just one neutral coming back to a typical AFCI breaker. However, GE’s AFCIs have the ability to fully protect against arc faults without monitoring the circuit neutrals. This allows you to wire a multi-wire or a shared neutral the same way you would with a thermal magnetic breaker.
  4. Can the AFCI with shared neutral be used for retrofit installations? Yes, for retrofit installation, GE AFCIs can be substituted for the existing thermal magnetic breakers without the need to sort out existing shared or mixed neutrals. For existing multi-wire or shared neutral applications, follow the same instructions as for new installations. For existing mixed neutral situations, the breaker will not nuisance trip because it is not monitoring the neutral. In addition, the existing neutrals do not need to be sorted and can be left on the neutral bar.
  5. How does this differ from other AFCIs that are on the market today? Most AFCIs require the neutral to come back to the circuit breaker to prevent the breaker from tripping. In retrofit installations where you would likely be replacing thermal magnetic circuit breakers, there is a high probability that there are neutral wires tied together throughout the house. This creates a situation where you would need to search out all of these wire runs, which can be a cumbersome, time-intensive process. GE’s AFCI with shared neutral eliminates the need to search these out because it can tolerate mixed neutral situations that are often encountered when replacing thermal magnetic circuit breakers. Information provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end-use conditions.
  6. How is the GE AFCI with shared neutral easier to install than other AFCI circuit breakers? With the GE AFCI, there is no need to hunt down mixed neutral runs. You just need to swap out the thermal magnetic breaker and wiring with the GE AFCI.
  7. Why can the GE AFCI breakers function with shared and mixed neutrals and others can’t? GE’s Patented Discrete Wavelet Transform Algorithm allows for accurate response to abnormalities in a circuit’s waveform caused by arcing conditions, without the need for a clean neutral return path. Unlike other brands, the neutral load lug provided on the GE AFCI breaker is there simply for your wiring convenience, and is purely optional. For new construction you have the option of returning the neutral wire to the breaker or simply to the neutral bar (as space allows). For retrofits it’s a true time-saver. You don’t have to track down the exact neutral wire that may be split or shared upstream– you can simply pull and replace.
  8. What if it’s easier to run the neutral wire back to the breaker instead of a ground bar? The GE AFCI breakers include lugs to support this wiring option as well. Every installation is different; the GE AFCI breakers provide the flexibility to wire it either way to suit the installation.
  9. Are there cost saving opportunities if I use a GE AFCI with shared and mixed neutral capability? There are potential savings in both time and materials costs. For new construction, the installer can take advantage of running one 3-wire conductor versus two 2-wire conductors, eliminating labor and material costs. For retrofit situations, GE’s AFCIs eliminate the need to hunt down mixed neutrals hidden in the dwelling, substantially reducing labor costs.
  10. Why is the GE AFCI only available in a one-pole version? The design of the GE AFCI eliminates the need to stock and inventory multiple pole versions. The NEC only requires arc fault protection on single pole 120 V circuits in dwellings. Therefore a traditional two and three pole offering is not required unless an installer wants to use shared neutrals. Installing a handle tie on the GE AFCI negates the need for anything more than a one-pole offering. With the GE AFCI you can use two one-poles (or even three one-poles with a handle tie in a 120/208V shared neutral application) and cover all applications. Plus, it is generally more economical than most factory two-pole AFCI options.
  11. Does the GE AFCI with shared and mixed neutral capability fit into existing panels? The GE AFCI circuit breakers will fit into existing GE panels. They are generally not listed for use in competitors’ panels and may void the Underwriters Laboratory (UL) rating if used in a non-GE panel. However, if it is the time to upgrade and change out the circuit breakers for AFCI circuit breakers, it is recommended that you also change out the panel. If you do install a new GE panel and AFCI circuit breakers, it will be a real time-saver compared with having to sort out the existing wiring.
  12. What approvals do the GE AFCI circuit breakers carry? The AFCI circuit breakers have UL and cUL approval.
  13. For residential installations, where should AFCIs be used? National Electrical Code (NEC) 2014 requires AFCI circuit protection in all dwelling areas of the home, which would typically include the kitchen, family room, dining room, bedrooms, sunrooms, hallways, closets, recreation rooms and other similar areas throughout a residence. For more information on NEC 2014 visit www.electricalcodecoalition.org.
  14. Do Dual Function Circuit Interrupter (DFCI) circuit breakers offer the same shared neutral advantage? Unfortunately, due to the added ground fault protection DFCIs provide, they do require a clean neutral return path to the circuit breaker. However for retrofits, if you are replacing a traditional ground fault circuit interrupter (GFCI) circuit breaker with a DFCI, the existing wiring would not be utilizing shared neutrals because of the GFCI protection, so the existing wiring can be exchanged for the new circuit breaker. In addition, the dual function protection can be achieved by using a standard AFCI and a GFCI receptacle at the first receptacle on the load end. This would almost eliminate the potential for mixed neutrals. If the circuit is using a ground fault receptacle that is functioning properly with additional downstream outlets, there will not be any mixed neutrals beyond the first receptacle.
  15. Where can I find more information about GE AFCI circuit breakers? www.geindustrial.com/residential or contact your local GE account manager.

Source: Arc Fault Circuit Interrupter (AFCI) with Shared Neutral

Why Aren’t My Outlets Working?

If your outlet is not working, there is a chance that you’ll need a pro to fix it, but some troubleshooting would come in handy.  You’ve already popped your popcorn for movie night, but when you turn on the TV …. nothing. But don’t panic—it’s not your TV that’s dead; it’s the outlet.

Outlet malfunctioning is a common problem homeowners face. In some cases, it’s not a bad idea to take a few troubleshooting steps to see if you can solve the problem yourself before calling Safe and Sound Electric. Here’s a guide to some of the most common reasons for a dead electrical outlet.

Safety warning: You have to take safety precautions when dealing with electricity. Unplug all devices and appliances from dead outlets. It’s also a good idea not to come near an electric plug or outlet without switching off the breaker from the main electric panel.

Why Does My Electrical Outlet Spark?

Some outlet sparks are normal, but short circuits, water exposure, and age can all cause dangerous sparks

Why Is My Electrical Outlet Not Working?

If you found yourself stuck with an electrical outlet that doesn’t work, it’s not always because of a major electrical problem. Here are some reasons you might be having trouble and troubleshooting tips to try before calling Safe and Sound Electric.

Switched Plugs

Sometimes outlets are controlled by wall switches, so you can turn on your electronics with a simple flip. So before you stress yourself out about your outlet not working, check to see that the switch is actually on first. It sounds like a silly thing to overlook, but (let’s be real) we’ve all been there.

A Problem With the Device Not the Outlet

Sometimes you think the outlet is dead, but the problem is actually with the device or appliance you’re trying to use. To make sure that’s not the issue, plug a different device into the same outlet. If it works, then it’s a problem with the device.

If you’re still not seeing results, check other outlets in the same room. Are they all dead? Now it’s time to call Safe and Sound Electric.

Tripped Breaker

If you tend to plug too many things into the same circuit, it can get overloaded when drawing more electricity than the circuit can handle, leading the circuit breaker to trip.

If your outlet doesn’t work, check the home breaker panel. If a breaker is tripped—the switch is in the middle, between ON and OFF—reset the breaker by flipping it to OFF and then back to ON.

If this doesn’t solve the problem and the breaker reverts back to the tripped position, this could be a sign you have a potentially dangerous situation, and you need to call Safe and Sound Electric right away.

Tripped GFCI Outlet

Many new buildings require GFCI outlets (ground-fault circuit interrupters) near sinks or damp areas. Instead of a flipped circuit breaker, this device shuts itself off (and the other outlets on the same circuit) when it detects excess heat.

When this happens, press the reset button on the outlet. If it doesn’t reset, you need to contact Safe and Sound Electric.

Faulty Outlet

Although it isn’t common, an outlet can burn out and quit functioning. If the outlet is faulty, you might want to consider having Safe and Sound Electric replace it.

Improper Installation

In some cases, the outlet doesn’t work because of an improper installation or loose connection, such as the following situations:

  • Backstabbing: Instead of using screws to connect wires to outlets, the wire is pushed into a connector inside the device. This creates a loose connection and causes the wires to burn out.
  • Incorrect use of wire nuts: Wire nuts keep all wires covered and tied together. But not using wire nuts properly will cause an outlet to stop functioning properly.
  • Loose connections: If any of the wires have come loose, they need reattaching—this problem is more common with old wiring.
    Contact Safe and Sound Electric to have your wires properly connected.

If you don’t know much about electricity, we recommend avoiding DIYing to avoid any dangerous mistakes. Electricians are trained to work with safety codes. Besides, they have special equipment and testers to help them locate and diagnose electrical issues that are difficult to pinpoint.

Is a Dead Outlet Dangerous?

Home electrical issues can be deadly serious, even causing house fires. This is why you should always take any electrical issue seriously.

If your electrical outlet is not working and signs of a burning smell, discolored outlet, or outlet spark appear, you need to talk to Safe and Sound Electric as soon as possible.

Source: Reasons Why Your Electrical Outlet Isn’t Working and What You Should Do

National Electrical Code Changes in 2020

The 2020 National Electric Code includes requirement updates in four significant areas: surge protection, GFCI protection, firemen’s disconnect and solar power. Be familiar with the official NEC codes in your state.

NEC 2020 includes four major updates to the existing 2017 electrical code:

  • GFCI protection is now required for 125–250V receptacles within 6 feet of sinks.
  • Surge protection is now required for lines feeding dwelling units.
  • Emergency disconnects are now required for all one- and two-family dwelling units.
  • Solar panels (California directive) are now required to have outdoor emergency disconnect.

NEC 2020 adoption is underway in:

  • Connecticut
  • Idaho
  • Iowa
  • Maine
  • Nebraska
  • New Hampshire
  • New Mexico
  • North Carolina
  • Ohio
  • Oregon
  • Rhode Island
  • Utah
  • Vermont

NEC 2020 Is in Effect in:

  • Colorado
  • Georgia
  • Massachusetts
  • Minnesota
  • North Dakota
  • South Dakota
  • Texas
  • Washington
  • Wyoming

GFCI (DWELLINGS)

GFCI protection is required for all 125–250V receptacles within 6 feet of sinks. Notable spaces include:

  • Laundry areas
  • Kitchens
  • Unfinished basements
  • Finished basements
  • Outdoor outlets 150V to ground or less and up to 50amps

This applies to:

  • Ranges within 6 feet of sinks
  • Electric dryers
  • Dishwashers
  • Sump pumps
  • Pool motors
  • Equipment that requires service, including HVAC and refrigeration units

GFCI protection is also required in non-dwellings. Notable spaces include:

  • Indoor damp and wet locations
  • Permanent fixtures for cooking
  • Permanent provisions for food preparation
  • Accessory buildings

This applies to:

  • Dishwashers
  • Drinking fountains
  • Sump pumps
  • Pool motors
  • Equipment that requires service, including HVAC and refrigeration units

Emergency Disconnects

  • Required for all single- and two-family dwellings
  • Must function from outside dwellings
  • Must be readily accessible
  • Applies to generators and energy storage systems (ESS)
  • Generators must be marked with one of the following:

EMERGENCY DISCONNECT, SERVICE DISCONNECT

EMERGENCY DISCONNECT, METER DISCONNECT, NOT SERVICE EQUIPMENT

EMERGENCY DISCONNECT, NOT SERVICE EQUIPMENT

Surge Protection

  • New article (242) includes service lines to dwelling units
  • Must be part of service equipment or adjacent
  • May be located at each level of downstream distribution

Now applies to:

  • Line side and load side services
  • Replacements and service upgrades

Solar (California)

  • Solar panels on new construction*
  • Outdoor disconnect required for all energy storage units

*The State of California requires solar photovoltaic systems for newly constructed healthcare facilities starting January 1, 2020.

NEC 2020 includes several new articles. Surge protection article 242 is one among four.Article 242 Overvoltage Protection combines articles 280 and 285 and addresses surge protective requirements, devices and arresters.Article 337 Type P Cable addresses 600V Type P cables used in industrial and hazardous areas and specifications.

Article 311 MV Conductors & Cable expands on deleted article 328 and addresses medium voltage conductors and cables, their use and specifications.

Article 800 General Requirements for Communications Systems consolidates the previous contents of 2017 NEC chapter 8 into one articles and addresses requirements for communication circuits, including television and radio distribution antennae and network powered broadband systems.

Removed Articles

NEC 2020 removes several articles present in NEC 2017 to improve clarity and limit redundancies. These are:

  • Article 280 SPDs over 1,000V
  • Article 285 SPDs 1,000V or less
  • Article 328 MV Cable Type MV
  • Article 553 Floating Buildings

The National Fire Protection Agency publishes official updates to the National Electrical Code every three years. These updates have run uninterrupted since 1897, when the code was introduced. 2020 NEC is the result of more than 5,000 public inputs and comments, 18 panels, the annual NFPA meeting and more than 2,000 revisions.

California Energy Commission, “2019 Building Energy Efficiency Standards.” 2018.

National Fire Protection Association, “Power Aid: GFCI Protection, Emergency Power Disconnects, and much more.” 2019.

National Fire Protection Association, “NEC Enforcement.” 2019.

Reproduced from NFPA’s website, © NFPA 2020.

Source National Electrical Code Changes in 2020

Debunking Six AFCI Myths

By William Atkinson Published In May 2017
An arc fault circuit interrupter (AFCI) is an advanced circuit breaker that, as a way to reduce electrical fire threats, breaks the circuit when it detects a dangerous electric arc in the circuit that it protects.

An AFCI is able to selectively distinguish between a harmless arc that is incidental to the normal operation of switches and plugs, versus a potentially dangerous arc that can occur, such as in a lamp cord with a broken conductor. An AFCI is designed to detect a wide range of arcing electrical faults that help reduce the electrical system from being an ignition source of a fire.

Despite the fact that AFCIs were introduced and written into electrical codes in the late 1990s (more on this later), several myths still surround AFCIs—myths often believed by homeowners, state legislators, building commissions, and even some electricians.

MYTH 1: AFCIs are not important when it comes to saving lives

“AFCIs are very important safety devices that have been proven time and again,” said Ashley Bryant, senior product manager for Siemens. In fact, according to Bryant, www.afcisafety.org includes several success stories on how these breakers have found some very dangerous situations and saved people and property.

Arc faults are one of the leading causes of residential electrical fires. Through the 1990s, according to the U.S. Consumer Product Safety Commission (CPSC), an average of over 40,000 fires a year were attributed to home electrical wiring, resulting in over 350 deaths and over 1,400 injuries. The CPSC also reported that over 50 percent of these fires could have been prevented with the use of AFCIs.

“The www.afcsafety.org website also includes a UL report noting that the average time to get out of a house in the event of a fire was 17 minutes,” she said. “These days, though, because of homes being larger, having more open floor plans and fewer drywall barriers, and furniture that catches fire easier, that is now down to three minutes.”

In addition, the CPSC reports that electrical fires due to arcing tend to occur behind walls, making them more dangerous. That is, these fires can spread undetected more quickly, they can cause more damage than other fires, and they end up being twice as deadly as fires not occurring behind walls, since homeowners tend not be aware of the fires behind walls until it may be too late to escape.

MYTH 2: AFCI manufacturers are driving expanded code requirements for the installation of AFCI

“I find this myth common when I am talking with legislators, but it is important that the electrical industry understand the reality as well when they are talking with their state senators and building commissions,” said Alan Manche, vice president, external affairs, for Schneider Electric.

[SB]The drive for the expanding code requirements are coming from third-party research.

“The Consumer Product Safety Commission and studies conducted by UL with regard to thousands of fires occurring in homes in late 1980s and early 1990s drove the need to address the causes of these fires,” Manche said. “Arc fault protection became the solution that was recognized by the CPSC, UL, and others.”

MYTH 3: AFCIs are only required by codes in a small number of rooms in residential homes

“The National Electrical Code has been expanding the reach of AFCIs beyond residential homes,” said Jim Phillips, P.E. president of Brainfiller.com, and a contributing editor to ELECTRICAL CONTRACTOR magazine.

The first National Electrical Code (NEC) requirement for AFCIs was released in 1999, requiring them to be installed to protect the circuits feeding bedrooms in new homes. In 2008, and again in 2014, the NEC was expanded to require AFCIs to be installed on circuits to more and more rooms in homes, now covering virtually all rooms—bedrooms, family rooms, dining rooms, living rooms, sunrooms, kitchens, dens, home offices, hallways, recreation rooms, laundry rooms, and even closets.

In addition, in 2014, the NEC also began requiring the use of AFCIs in college dormitories. It has also expanded requirements to include hotel/motel rooms that offer permanent provisions for cooking.

MYTH 4: An AFCI only protects what is plugged into the specific defective outlet that triggers the electric arc

“An AFCI actually protects the entire circuit,” said Rich Korthauer, vice president, final distribution business, for Schneider Electric. “This includes the electrical panel; the downstream wires that run through the walls; the outlets; the switches; all of the connections to those wires, outlets and switches; and anything that is plugged into any of those outlets and connected to switches on that circuit.

MYTH 5: A standard circuit breaker will provide just as much protection as an AFCI


Conventional circuit breakers only respond to overloads and short circuits. They do not protect against arcing conditions that produce erratic and often reduced current.

“A standard circuit breaker protects the insulation on a wire from an overload,” Korthauer said. “It is not intended to identify bad arcs on circuits in the home. Of course, if you have a dead short, a standard circuit breaker is designed to trip and interrupt that condition.”

MYTH 6: Most AFCI “trips” are the result of “nuisance tripping”


“I hear this myth a lot,” Siemens’ Bryant said. “People believe that certain arc fault breakers are defective because they frequently trip. People need to think of these not as ‘nuisance tripping,’ but rather as ‘safety alerts.’ The majority of the time, these breakers trip because they are supposed to. They are tripping due to some type of arcing event on the circuit.”

This can especially be true with “stab” receptacles, where wires are spring-loaded into the backs of the receptacles, instead of wiring around screws, which provide firm connections. In many instances, according to Bryant, when homeowners jam plugs into spring-loaded receptacles or pull them out roughly, it jostles the receptacles, allowing the wires to come loose, which will cause the arc fault breakers to trip.

“Again, this is not ‘nuisance tripping,” she said. “It is a ‘safety alert.’”

Debunking Six AFCI Myths | Electrical Contractor Magazine (ecmag.com)

Electromagnetic Fields

All of us depend on electricity to meet basic needs such as heating, cooling and lighting our homes. We also depend on electricity to meet the transportation, communication, commercial, recreational, industrial and health care requirements of our society. Wherever we make use of electricity, power frequency electric and/or magnetic fields (EMF) are present.

EMF is measured in milligauss (mG). Most research on the potential health effects of EMF has focused on magnetic fields.

Electric fields

Electric fields are created around appliances and wires wherever a voltage exists. You can think of electric voltage as the pressure of water in a garden hose – the more voltage, the higher the electric field strength. Electric fields are present when an electrical appliance is plugged in even when turned off. Electric fields diminish rapidly with distance from the source and can be shielded by objects such as trees or the walls of a building.

Magnetic fields

Magnetic fields are created whenever there is a flow of electric current. This can be thought of as the flow of water in a garden hose. As the amount of current flowing increases, so does the magnetic field. Magentic fields are only present when there is a flow of electricity, such as when an electrical appliance is operating. Magenetic fields diminish rapidly with distance from the source, but are not shielded by objects such as trees or buildings. The level of magnetic fields from electrical appliances in homes can be as high as or higher than the magnetic fields people may experience under power lines. Magnetic field strength from power lines depend on many factors, including the design of the line, the amount of current the line carries, and the distance from the line.

Research on EMF – How it affects you

You may have questions about whether there are adverse health effects from exposure to power frequency EMF. For over 40 years, there have been many scientific studies conducted on power frequency EMF. Extensive reviews and research conducted by leading public health agencies – such as the World Health Organization (WHO) and the U.S. National Institute of Environmental Health Sciences (one of the U.S. National Institutes of Health) – have not established that exposure to power frequency EMF causes adverse health effects in humans or animals. In the view of WHO, “Based on a recent in-depth review of the scientific literature, the WHO concluded that current evidence does not confirm the existence of any health consequences from exposure to low level electromagnetic fields.”

Two principal types of studiest have been conducted on power frequency EMF: laboratory studies and epidemiology studies.

Laboratory studies

Laboratory studies involve exposing cells, tissues and animals to EMF under controlled conditions in the laboratory. Many laboratory studies have examined whether cells exposed to EMF show significant permanent damage to the structure of DNA or chromosomes that could lead to the development of cancer. Other studies have examined whether adverse health effects are found in animals exposed to power frequency EMF for their entire lives. The reviews conducted by leading public health agencies, such as WHO and NIEHS have found that the laboratory studies do not show that exposure to power frequency EMF causes adverse effects in cells or animals.

Epidemiology studies

Epidemiology studies look for statistical associations between the incidence of disease and specific conditions or exposures. Some epidemiology studies have reported a weak statistical association between estimates of EMF exposures and some cancers, while other epidemiology studies have not found such an association. Leading public health agencies, such as WHO and NIEHS have found that, at most, these epidemiology studies can be interpreted as showing a “possible” but inconclusive relationship between EMF and childhood leukemia, and that the relationship is weak and lacks support from the laboratory research. As noted by WHO, “Despite extensive research, to date there is no evidence to conclude that exposure to low level electromagnetic fields is harmful to human health.”

Exposure limits

Neither the U.S. government nor the state of Washington has established exposure standards for public exposure to power frequency EMF. Two international organizations, the International Commission on Non-Ionizing Radiation Protection (ICNIRP) and the Institute of Electrical and Electronic Engineers (IEEE), have developed exposure guidelines that have been endorsed by the World Health Organization (WHO).

Established EMF exposure limits
International Commission on Non-Ionizing Radiation Protection2,000 mG1
Institute of Electrical and Electronic Engineers9,040 mG
1In November 2010, ICNIRP updated its guidelines. These guidelines replace the prior exposure guidelines ICNIRP issued in 1998. Exposure limits under the new guidelines more than doubled: from 833 mG to 2,000 mG. See “ICNIRP Statement – Guidelines for Limiting Exposure to Time-Varying Electric and Magnetic Fields (1 Hz to 100 kHz)” and “Fact Sheet on the Guidelines for Limiting Exposure to Time-Varying Electric and Magnetic Fields (1 Hz to 100 kHz)” at www.icnirp.org.

Everyone’s Safety is our Priority

If you or someone you love has concerns about EMF, noisy electrical equipment, or flickering lights Contact an “Electrician Near Me” Safe and Sound Electric

Source PSE | Puget Sound Energy | Electric Current in Electromagnetic Fields

11 Shocking Home Electrical Safety Tips

Sparks fly, a couch burns and the rest of us get some critical lessons in dealing with circuit breakers and electrical fires.

Source: 11 Shocking Home Electrical Safety Tips

Listen to your breaker.

A breaker that trips immediately after it’s reset is telling you that there’s an electrical problem. Sure, sometimes the breaker itself is to blame, and in some cases there may just be too large an electrical load operating on that circuit. But it’s more likely that the breaker is tripping because there’s a severe electrical problem. Keep pressing that breaker, and you’re likely to cause a fire.

Know when to fight and when to flee.

Firefighters recommend that if you have any doubt about fighting a fire, you’re best bet is to get out of the house as quickly as possible. Once you’re safely outside, call the fire department. If you decide that there’s a reasonable chance that you can fight a fire and win, then stand your ground, but don’t let the fire get between you and the exit. If you sense that the fire’s going to overtake you and block your exit, get out.

Never throw water on an electrical fire.

This will be obvious to many PM readers, but in the heat (ahem) of the moment, grabbing a bucket of water can seem tempting, if unreasonable. Water conducts electricity (this is why you don’t want to be in a lake during a lightning storm), so throwing water on the fire could cause it to get larger. Instead, use your chemical fire extinguisher.

Use your fire extinguisher effectively.

Firefighters recommend the time-honored PASS method:

Pull the fire extinguisher’s safety pin.

Aim the extinguisher nozzle at the base of the fire.

Squeeze the extinguisher’s handle.

Sweep the extinguisher’s nozzle in a side-to-side motion until the flames are out.

Sure, it sounds easy, but let’s hope you never have to use this advice. Start by paying attention to what the circuit breaker is telling you. If it trips immediately, evaluate the situation if you are electrically competent or call an electrician. Don’t call Pat, though; he’s already got enough to do.

Aside from blatantly obvious electrical malfunctions that lead to flying sparks or circuit breakers that trip repeatedly, you should always keep a sharp eye cocked for more subtle telltale electrical-danger signs:

Lights that flicker or that trip the circuit breaker

Cause: Loose wiring splice or a light fixture that’s worn out and needs to be replaced.

Solution: Cut power to the fixture and investigate the supply wiring and the fixture itself. Replace wire connectors with new professional-grade types. Replace the fixture if suspect.

Outlets with a faceplate that’s warm to the touch

Cause: An overly large electrical load operating on that outlet, undersized wiring or a loose electrical splice. (Note: it’s not unusual for dimmer switches, especially large ones, to be warm. Unless the switch face is actually too hot to touch, a warm dimmer is not a hazard in most cases)

Solution: Cut power and investigate. Look for a loose splice, melted connections, burned insulation. Repair as necessary. Also, evaluate wattage of device; it may be too large relative to supply wiring. Move device to another circuit, preferably one served by a 20-amp circuit breaker and 12-gauge wire. If condition persists, contact an electrician.

Extension cords wrapped in electrical tape or with loose ends

Cause: Wear and tear has taken its toll on the cord.

Solution: Cut off damaged sections of cords; replace loose or damaged male/female ends. Replace severely damaged cords.

Wobbly switches or outlet receptacles

Cause: Device is improperly mounted to the electrical box or the box itself has come loose from the stud.

Solution: Cut power. Remove faceplate and tighten mounting screws. Occasionally, overly long screws will not fully seat. Shorten screws with an electrician’s multitool (a pair of pliers that strip wire, bend wire and cut screws ). Reinstall device. Otherwise, tighten connection of box to framing.

Ceiling fans that slowly wobble

Cause: Fan is out of balance or may be installed on a box that’s not listed for supporting a fan.

Solution: Balance fan or cut power and reinstall fan, checking for loose, damaged or missing hardware. If necessary, replace box. Use a retrofit/old-work box rated for fan installation (note: These are not to be confused with old-work boxes or other electrical boxes not listed for fan installation. Specialized retrofit boxes rated for fans tend not to be common hardware-store or home-center items. Visit an electrical supply house or use a Web-based supplier. One version is the Steel One Box manufactured by Arlington Products. (www.aifittings.com).

GFCI outlets that trip repeatedly

Cause: A ground fault or a worn-out GFCI outlet receptacle.

Solution: Move appliance or tool to another GFCI and test. If GFCI trips, appliance or tool is suspect. If GFCI does not trip, electrical problems are likely. Cut power and investigate for damaged wire insulation, a loose splice or a small length of exposed wire making contact with a metal electrical box. If you don’t find wiring or splice problems, replace the GFCI. If condition persists, contact an electrician.

The beer fridge in the garage that occasionally gives you a small shock

Cause: Many an old refrigerator will have a tiny leakage current because of worn-out insulation on its internal wiring, especially if it has a defrost circuit. This phenomenon is well-known and can even be quite dangerous when the refrigerator is placed on an electrically conductive concrete floor, especially a floor that’s damp with condensation.

Solution: Replace the refrigerator with a new energy-conserving model.